Simple distance-based thread analytical device integrated with ion imprinted polymer for Zn2+ quantification in human urine samples
บทความในวารสาร
ผู้เขียน/บรรณาธิการ
กลุ่มสาขาการวิจัยเชิงกลยุทธ์
รายละเอียดสำหรับงานพิมพ์
รายชื่อผู้แต่ง: Lita Chheang, Kawin Khachornsakkul, Ruben Del-Rio-Ruiz, Wenxin Zeng, Nisakorn Thongkon, Sudtida Pliankarom Thanasupsine, Sameer Sonkusale
ผู้เผยแพร่: Royal Society of Chemistry
ปีที่เผยแพร่ (ค.ศ.): 2024
วารสาร: Analyst (0003-2654)
Volume number: 149
Issue number: 11
หน้าแรก: 3161
หน้าสุดท้าย: 3168
จำนวนหน้า: 8
นอก: 0003-2654
eISSN: 1364-5528
URL: https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00076e
ภาษา: English-United States (EN-US)
บทคัดย่อ
This article presents the development of a distance-based thread analytical device (dTAD) integrated with an ion-imprinted polymer (IIP) for quantitative monitoring of zinc ions (Zn2+) in human urine samples. The IIP was easily chemically modified onto the thread channel using dithizone (DTZ) as a ligand to bind to Zn2+ with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as well as 2,2-azobisisobutyronitrile (AIBN) as cross-linking agents to enhance the selectivity for Zn2+ detection. The imprinted polymer was characterized using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectroscopy and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy (SEM-EDS). Under optimization, the linear detection range was from 1.0 to 20.0 mg L-1 (R2 = 0.9992) with a limit of detection (LOD) of 1.0 mg L-1. Other potentially interfering metal ions and molecules did not interfere with this approach, leading to high selectivity. Furthermore, our technique exhibits a remarkable recovery ranging from 100.48% to 103.16%, with the highest relative standard deviation (% RSD) of 5.44% for monitoring Zn2+ in human control urine samples, indicating high accuracy and precision. Similarly, there is no significant statistical difference between the results obtained using our method and standards on zinc supplement sample labels. The proposed method offers several advantages in detecting trace Zn2+ for point-of-care (POC) medical diagnostics and environmental sample analysis, such as ease of use, instrument-free readout, and cost efficiency. Overall, our developed dTAD-based IIP method holds potential for the simple, affordable, and rapid detection of Zn2+ levels and can be applied to the analysis of other metal ions.
คำสำคัญ
ไม่พบข้อมูลที่เกี่ยวข้อง