A label-free electrochemical immunosensor based on MWCNT-COOH/dPEDOT for early detection of Alzheimer's disease biomarker p-Tau 217

บทความในวารสาร


ผู้เขียน/บรรณาธิการ


กลุ่มสาขาการวิจัยเชิงกลยุทธ์


รายละเอียดสำหรับงานพิมพ์

รายชื่อผู้แต่งAriyasajjamongkol N.; Thongwattana N.; Luechaipanit W.; Haethaisong T.; Chongsuksantikul A.; Oangkhana P.; Thanapornsangsuth P.; Paradee N.; Phasuksom K.; Sirivat A.

ผู้เผยแพร่Elsevier

ปีที่เผยแพร่ (ค.ศ.)2025

วารสารJournal of Electroanalytical Chemistry (1572-6657)

Volume number992

นอก1572-6657

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-105008806878&doi=10.1016%2fj.jelechem.2025.119281&partnerID=40&md5=225ce8b4b31add7b8f9c724cf4f24388

ภาษาEnglish-Great Britain (EN-GB)


ดูบนเว็บไซต์ของสำนักพิมพ์


บทคัดย่อ

Phosphorylated tau protein at threonine 217 (p-Tau 217) has emerged as a significant biomarker for Alzheimer's disease (AD). In this study, a label-free electrochemical immunosensor (LBEI) was developed for p-Tau 217 detection by utilizing acid-treated multiwalled carbon nanotubes (MWCNT-COOH) and doped poly(3,4-ethylenedioxythiophene) (dPEDOT). The incorporation of dPEDOT enhances the electrical conductivity of the electrode, facilitating improved sensor performance. The MWCNTs were functionalized with carboxyl groups (COOH) and activated using EDC-NHS chemistry to serve as effective linkers for antibody immobilization. The concentrations of p-Tau 217 were quantified using differential pulse voltammetry (DPV). This technique was not previously reported for p-Tau 217 detection. In addition, the calibration of the immunosensor with two commercial synthetic p-Tau 217 were nearly identical results, confirming the accuracy of the immunosensor. The immunosensor exhibited a wide-range calibration curve across three concentration regimes from 0.1 to 105 pg/mL, with a limit of detection (LOD) of 0.1 pg/mL. The immunosensor performances also demonstrated acceptable selectivity, stability, and reproducibility. Furthermore, the sensor successfully detected p-Tau 217 in human cerebrospinal fluid (CSF), illustrating its potential for practical clinical applications. This study highlights the potential of label-free electrochemical immunosensors incorporating MWCNT-COOH/dPEDOT as highly efficient and promising platforms for the development of portable diagnostic devices for the clinical detection of Alzheimer's disease. © 2025 Elsevier B.V.


คำสำคัญ

ไม่พบข้อมูลที่เกี่ยวข้อง


อัพเดทล่าสุด 2025-17-07 ถึง 00:00