Cyclic operation of porous combustor-heater (PCH)

Journal article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listJugjai S., Nungniyom V.

PublisherElsevier

Publication year2009

JournalFuel: The Science and Technology of Fuel and Energy (0016-2361)

Volume number88

Issue number3

Start page553

End page559

Number of pages7

ISSN0016-2361

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-59549102983&doi=10.1016%2fj.fuel.2008.10.004&partnerID=40&md5=b55640b57bcd32160a409cb3c92a6766

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

A porous combustor-heater (PCH) with cyclic flow reversal combustion (CFRC) was investigated on the basis of simulation for practical applications. Emphasis was placed on determination of the optimal switching period under which the system will offer a high thermal efficiency with low emissions. It was shown that by using the CFRC thermal performance, emissions are strongly affected by the switching period through the interaction of the hot zone movement within the reactor and by heat transfer to the tube bank. An optimal switching period of about 120-180 s was found with maximum thermal efficiency to be as high as 85% with low emissions of CO and NOx of 200 and 20 ppm, respectively. The CFRC system yields higher thermal efficiency with higher combustion efficiencies than the unidirectional steady state regime at the same experimental conditions. ฉ 2008 Elsevier Ltd. All rights reserved.


Keywords

Cyclic flow reversal combustionPorous combustor-heaterPorous media


Last updated on 2023-14-10 at 07:35