Dual scalar controlled drives of induction motors using single voltage source inverter for long cable applications

Conference proceedings article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listTongkhundam G., Konghirun M.

PublisherHindawi

Publication year2008

Start page1826

End page1831

Number of pages6

ISBN9781424418749

ISSN0146-9428

eISSN1745-4557

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-49249123365&doi=10.1109%2fAPEC.2008.4522975&partnerID=40&md5=69e1d0d6a2780cb2bb9ddf8fc60ff34a

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

This paper presents dual scalar controlled drives of induction motors using single voltage source inverter through long feeding cables. As known, when the cable length is long, over-voltages at motor terminal could be doubled from the pulsed output voltage at inverter terminal. In this paper, a half DC-link inverter is implemented to drive two motors simultaneously for different configurations of cable lengths. The implemented inverter drastically reduces the over-voltage at both motor terminals with a proper duration time of V dc/2 level (β). Simulation and experimental results are provided to show the effectiveness of over-voltage reduction by using this inverter. According to these results, for two motors with different cable lengths, this β should be calculated based on the cable length closed to the longer one. ©2008 IEEE.


Keywords

Half DC-link inverterInduction motor


Last updated on 2023-04-10 at 07:35