Design of a cascaded H-bridge converter for insulation testing

Conference proceedings article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listKongnun W., Sangswang A., Chotigo S.

PublisherHindawi

Publication year2009

Start page859

End page863

Number of pages5

ISBN9781424443499

ISSN0146-9428

eISSN1745-4557

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-77950155886&doi=10.1109%2fISIE.2009.5222728&partnerID=40&md5=7d284d434a8443c39440fe7d5c23f870

LanguagesEnglish-Great Britain (EN-GB)


View on publisher site


Abstract

This paper describes a design of a cascaded H-bridge converter for insulation testing of the crosslinked polyethylene (XLPE) cable. This high voltage generator produces a sinusoidal waveform at a very low frequency (VLF) of 0.1 Hz. The design of the cascaded H-bridge converter consists of two main parts, a modulation unit and a switching unit. The modulation unit compares the 0.1 Hz reference sinusoidal waveform with the 10 kHz of carrier waveform. The switching unit consists of 6 H-bridge modules using phase disposition (PD) multicarrier modulation scheme to generate 13 levels of PWM signals. The cascaded H-bridge converter can covert the high voltage direct current (HVDC) to multilevel step-pulse signals and change to the sinusoidal waveform at 0.1 Hz by the low-pass filter. The use of multilevel H-bridge converter helps reduce the total harmonic distortion (THD) from single level H-bridge converters. The experimental results show that the THD value is less than 5% complied to the IEEE 400.2 standards. ฉ2009 IEEE.