Effect of oxygen pressure and flow rate on electrical characteristic and ozone concentration of a cylinder-cylinder DBD ozone generator

Conference proceedings article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listBoonduang S., Limsuwan S., Kongsri W., Limsuwan P.

PublisherElsevier

Publication year2012

Volume number32

Start page936

End page942

Number of pages7

ISSN1877-7058

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84892612731&doi=10.1016%2fj.proeng.2012.02.035&partnerID=40&md5=1ad7062b13919976ff157a2652d4472c

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

A cylinder-cylinder dielectric-barrier discharge (DBD) ozone generator was developed. In order to investigate the optimum conditions for the effective ozone generation in a cylinder-cylinder DBD, the measurements of ozone concentration were carried out for various oxygen pressures and oxygen flow rates. At each condition, the electrical characteristics such as discharge voltage, current, power and their waveforms were recorded. It was found that, for all oxygen pressures, the optimum discharge voltage occurred at an oxygen flow rate of 12 L/min which led to the maximum ozone yield of about 14 g/h at an oxygen pressure of 1.1 atm. However, the maximum ozone concentration of about 80 g/m3 was obtained at an oxygen pressure of 1.1 atm and an oxygen flow rate of 12 L/min. ฉ 2010 Published by Elsevier Ltd.


Keywords

Cylinder-cylinder DBDOzone concentrationOzone generator


Last updated on 2023-04-10 at 07:36