Analytical solutions for membrane wetting calculations based on log-normal and normal distribution functions for CO2 absorption by a hollow fiber membrane contactor

บทความในวารสาร


ผู้เขียน/บรรณาธิการ


กลุ่มสาขาการวิจัยเชิงกลยุทธ์

ไม่พบข้อมูลที่เกี่ยวข้อง


รายละเอียดสำหรับงานพิมพ์

รายชื่อผู้แต่งBoributh S., Jiraratananon R., Li K.

ผู้เผยแพร่Elsevier

ปีที่เผยแพร่ (ค.ศ.)2013

วารสารJournal of Membrane Science (0376-7388)

Volume number429

หน้าแรก459

หน้าสุดท้าย472

จำนวนหน้า14

นอก0376-7388

eISSN1873-3123

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84871911440&doi=10.1016%2fj.memsci.2012.11.074&partnerID=40&md5=91ea583947deb8b709ab157f05a0a803

ภาษาEnglish-Great Britain (EN-GB)


ดูในเว็บของวิทยาศาสตร์ | ดูบนเว็บไซต์ของสำนักพิมพ์ | บทความในเว็บของวิทยาศาสตร์


บทคัดย่อ

The analytical solutions for calculating the average wetting ratio, 〈x*〉, for gas-liquid membrane contacting process based on log-normal and normal distribution functions have been developed. By using the membrane characteristics, liquid absorbent properties and operating conditions, the average wetting ratio is determined analytically. The overall mass transfer coefficient (KG) corresponding to the average wetting ratio is also calculated. Due to the pressure drop of liquid flow in the fiber, the operation mode would be changed along the fiber and six possible situations of operation cases are observed. In addition, the proposed calculation can predict the fiber lengths that are completely wetted, partially wetted and are completely dry. In order to verify the proposed calculation, the experiments of CO2 absorption from the gas mixture (CO2-N2) by polyvinylidenefluoride (PVDF) hollow fiber membrane contactor using water and monoethanolamine (MEA) as the absorbents were performed at various inlet liquid pressures (PL0) and liquid velocities. The results obtained from the experiments were reported in term of overall mass transfer coefficient and were validated with those obtained from the proposed calculations. It reveals that calculation based on log-normal distribution shows a better fit with the experiments compared to that based on normal distribution at all operating conditions indicating that the membrane pore structure can be described better using log-normal distribution function. In addition, the calculated average wetting ratio based on log-normal distribution function greed well with that obtained from the numerical model proposed in the literature. © 2012 Elsevier B.V.


คำสำคัญ

Hollow fiber membrane contactorLog-normal distributionNormal distributionWetting


อัพเดทล่าสุด 2023-26-09 ถึง 07:36