Improvement of cooling performance of a thermoelectric air cooling system using a vapor chamber heat sink

Journal article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listLertsatitthanakorn C., Tipsaenprom W., Rungsiyopas M.

PublisherSpringer

Publication year2014

JournalJournal of Electronic Materials (0361-5235)

Volume number43

Issue number6

Start page1554

End page1559

Number of pages6

ISSN0361-5235

eISSN1543-186X

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84901820441&doi=10.1007%2fs11664-013-2791-9&partnerID=40&md5=1cf5de8982b18d55b2819fb6806894a5

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

Since vapor chambers exhibit excellent thermal performance, they are suited to use as the basis of a heat sink. This work presents the results of tests carried out to investigate the potential application of a vapor chamber heat sink for improving the cooling performance of a thermoelectric (TE) air cooling system. To this end, two sets of TE air coolers were constructed. The cold side of the TE module of both sets was fixed to a conventional plate-fin heat sink. The hot side of one set was fixed to a vapor chamber heat sink, whereas the other set was fixed to a conventional plate-fin heat sink. The effects of air flow rate and electric current supplied to the TE module on the cooling performance were considered. Experimental data were compared with corresponding data for a conventional plate-fin heat sink. It also has been experimentally proven that the use of a vapor chamber heat sink increases the coefficient of performance (COP) by up to 34.2%. ฉ 2013 TMS.


Keywords

COPHeat sink


Last updated on 2023-03-10 at 07:35