Modelling of a tubular solid oxide fuel cell with different designs of indirect internal reformer

Journal article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listKim-Lohsoontorn P., Priyakorn F., Wetwatana U., Laosiripojana N.

Publication year2014

Volume number23

Issue number2

Start page251

End page263

Number of pages13

ISSN2095-4956

eISSN2095-4956

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84898063946&doi=10.1016%2fS2095-4956%2814%2960143-1&partnerID=40&md5=1e47216788046584ba7146c8a8b35523

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

The cell performance and temperature gradient of a tubular solid oxide fuel cell with indirect internal reformer (IIR-SOFC) fuelled by natural gas, containing a typical catalytic packed-bed reformer, a catalytic coated wall reformer, a catalytic annular reformer, and a novel catalytic annular-coated wall reformer were investigated with an aim to determine the most efficient internal reformer system. Among the four reformer designs, IIR-SOFC containing an annular-coated wall reformer exhibited the highest performance in terms of cell power density (0.67 Wทcm-2) and electrical efficiency (68%) with an acceptable temperature gradient and a moderate pressure drop across the reformer (3.53 ื 10-5 kPa). IIR-SOFC with an annular-coated wall reformer was then studied over a range of operating conditions: inlet fuel temperature, operating pressure, steam to carbon (S: C) ratio, gas flow pattern (co-flow and counter-flow pattern), and natural gas compositions. The simulation results showed that the temperature gradient across the reformer could not be decreased using a lower fuel inlet temperature (1223 K-1173 K) and both the power density and electrical efficiency of the cell also decreased by lowering fuel inlet temperature. Operating in higher pressure mode (1-10 bar) improved the temperature gradient and cell performance. Increasing the S: C ratio from 2: 1 to 4: 1 could decrease the temperature drop across the reformer but also decrease the cell performance. The average temperature gradient was higher and smoother in IIR-SOFC under a co-flow pattern than that under a counter-flow pattern, leading to lower overpotential and higher cell performance. Natural gas compositions significantly affected the cell performance and temperature gradient. Natural gas containing lower methane content provided smoother temperature gradient in the system but showed lower power density and electrical efficiency. ฉ 2014 Dalian Institute of Chemical Physics, the Chinese Academy of Sciences. Published by Elsevier B.V.


Keywords

annular-coated wall reformercatalytic annular reformercatalytic coated wall reformerpacked-bed reformer


Last updated on 2023-28-09 at 07:35