Hydrogels of polyaniline with graphene oxide for highly sensitive electrochemical determination of lead ions

Journal article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listMuralikrishna S., Nagaraju D.H., Balakrishna R.G., Surareungchai W., Ramakrishnappa T., Shivanandareddy A.B.

PublisherElsevier

Publication year2017

JournalAnalytica Chimica Acta (0003-2670)

Volume number990

Start page67

End page77

Number of pages11

ISSN0003-2670

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85029636570&doi=10.1016%2fj.aca.2017.09.008&partnerID=40&md5=3f6d075efdc858e3c2df2edde49c2961

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

Conducting polymers with graphene/graphene oxide hydrogels represent a unique class of electrode materials for sensors and energy storage applications. In this article, we report a facile in situ method for the polymerisation of aniline resulting in the decoration of 1D conducting polyaniline (PANI) nanofibers onto the surface of 2D graphene oxide (GO) nanosheets followed by hydrogel formation at elevated temperature. The synthesized nanomaterial exhibits significant properties for the highly sensitive electrochemical determination as well as removal of environmentally harmful lead (Pb2+) ions. The square wave anodic stripping voltammetry (SWASV) determination of Pb2+ ions showed good electroanalytical performance with two linear ranges in 0.2–250 nM (correlation coefficient = 0.996) and 250–3500 nM (correlation coefficient = 0.998). The developed protocol has shown a limit of detection (LOD) of about 0.04 nM, which is much lower than that of the World Health Organization (WHO) threshold limits. The prepared electrode showed an average of ∼99.4% removal of Pb2+ ions with a relative standard deviation (RSD) of 3.4%. Selectivity of the electrode towards Pb2+ ions were tested in presence of potential interferences such as Na+, K+, Ca2+, Mg2+, Cu2+, Cd2+, Hg2+, Zn2+, Co2+, Ni2+, Fe2+ and Fe3+ of similar and higher concentrations. The sensor showed good repeatability and reproducibility. The developed protocol was used to analyse samples from industrial effluents and natural water samples. The results obtained were correlated with atomic absorption spectroscopy (AAS). © 2017 Elsevier B.V.


Keywords

Lead ions sensingPolyaniline-graphene oxide hydrogelSquare wave anodic stripping voltammetryToxic heavy metal ionswater treatment


Last updated on 2023-28-09 at 07:35