Experimental study on two-phase condensation heat transfer and pressure drop of R-134a flowing in a dimpled tube
Journal article
Authors/Editors
Strategic Research Themes
No matching items found.
Publication Details
Author list: Aroonrat K., Wongwises S.
Publisher: Elsevier
Publication year: 2017
Journal: International Journal of Heat and Mass Transfer (0017-9310)
Volume number: 106
Start page: 437
End page: 448
Number of pages: 12
ISSN: 0017-9310
eISSN: 1879-2189
Languages: English-Great Britain (EN-GB)
View in Web of Science | View on publisher site | View citing articles in Web of Science
Abstract
This study investigates the heat transfer and pressure drop of R-134a during condensation inside a dimpled tube. The test section is a horizontal counter-flow double-tube heat exchanger with refrigerant flowing in the inner tube and cold water flowing in the annulus. The inner tubes consist of one smooth tube and one dimpled tube, which are made from copper. The length and inner diameter of the test tube are 1500 mm and 8.1 mm, respectively. The test runs are performed at saturation temperatures of 40, 45, and 50 °C, heat fluxes of 10, 15, and 20 kW/m2, and mass fluxes of 300, 400, and 500 kg/m2 s. The effects of heat flux, mass flux, and saturation temperature on the heat transfer coefficient and frictional pressure drop are examined. Comparisons between smooth and dimpled tubes on the heat transfer and frictional pressure drop are also discussed. It is observed that the heat transfer coefficient and frictional pressure drop obtained from a dimpled tube are higher than that of the smooth tube. In addition, as the equivalent Reynolds number increases, the dimpled tube enhances the Nusselt number around 1.3–1.4 times in comparison to the smooth tube. Whereas, when the equivalent Reynolds number decreases, the two-phase friction factor rises around 2.8–4.1 times as compared to the smooth tube. © 2016 Elsevier Ltd
Keywords
Dimpled tube