Investigation of indirect benefits of PV rooftop in Thailand

Conference proceedings article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listKhumkrong T., Chuangchote S., Chenvidhya D., Kirtikara K.

PublisherIOP Publishing

Publication year2017

Volume number67

Issue number1

ISSN1755-1307

eISSN1755-1315

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85020901363&doi=10.1088%2f1755-1315%2f67%2f1%2f012019&partnerID=40&md5=c81ae3ff906da1df9ad56893125877d3

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

Other than electricity generation, which is the direct benefit of PV rooftop, cooling load reduction due to PV shading is a benefit impact in the uses of PV rooftop. This report is a study of those indirect benefits of PV rooftop. Relation of shading of PV modules and reduction of cooling load was studied in a real testing cite at the office building of CES Solar Cell Testing Center (CSSC). Several data, i.e. solar radiation, rooftop temperatures before/after PV-panel installation, and electricity consumed by equipment, were monitored and collected. This data could be further estimated for cooling load via transient heat conduction approach. ฉ Published under licence by IOP Publishing Ltd.