Load Profiles in Grid-Connected Residential Buildings: Experimental Studies with Rooftop PV and Battery Systems

บทความในวารสาร


ผู้เขียน/บรรณาธิการ


กลุ่มสาขาการวิจัยเชิงกลยุทธ์

ไม่พบข้อมูลที่เกี่ยวข้อง


รายละเอียดสำหรับงานพิมพ์

รายชื่อผู้แต่งChukiat Jangjun;Chukiat Jangjun;Surawut Chuangchote;Athikom Bangviwat;Athikom Bangviwat;Dhirayut Chenvidhya

ปีที่เผยแพร่ (ค.ศ.)2019

วารสารSuan Sunandha Rajabhat University Journal of Science and Technology (2351-0889)

Volume number6

Issue number1

หน้าแรก15

หน้าสุดท้าย20

นอก2351-0889

eISSN2539-5742

URLhttp://www.ssstj.sci.ssru.ac.th/Content/journals/Volume6_No1/Vol6_No1_003.pdf


บทคัดย่อ

The number of photovoltaic (PV) installation in many countries has increased in the past decades. The advantages of energy from PV consists of reduction of CO2 emission, low maintenance cost, low operation cost, etc. On the other hand, the main problems of this technology consist of: (1) electrical power is relatively fluctuated and (2) the excessive energy from PV generating cannot be stored for any use in another necessary time. One of the solving solution is the integration of the PV systems with battery systems to keep the system stability. Moreover, the reduction of battery price leads the electricity users interest in the installation of battery systems with rooftop PV on their buildings. In the past, a number of works studied on PV systems with integrated batteries as the off-grid systems and evaluated by simulation programs. In this work, the load profiles of buildings in different categories (i.e. households, small offices, and home offices) of residential section are discussed. The characteristics of load profiles in residential buildings installed with a grid-connected rooftop PV system with batteries are analyzed by physical experimentations. It was found that battery systems were significantly affected the load profiles of the residential buildings. Household was found to be the highest proportion (21.68%) of excessive electricity. The ratio of PV met to load (29.15%) was smaller than the ratio of battery charging (50.17%). In addition, the excessive electricity in small office was the lowest proportion (10.39%), while the ratio of PV met to load (57.83%) was higher than the battery charging (31.78%).


คำสำคัญ

Battery systemLoad profile


อัพเดทล่าสุด 2022-06-01 ถึง 15:37