Field and three-dimensional finite element investigations of the failure cause and rehabilitation of a composite soil-cement retaining wall
Journal article
Authors/Editors
Strategic Research Themes
Publication Details
Author list: Jamsawang P, Voottipruex P, Jongpradist P, Likitlersuang S
Publisher: Elsevier
Publication year: 2021
Journal: Engineering Failure Analysis (1350-6307)
Volume number: 127
ISSN: 1350-6307
eISSN: 1873-1961
URL: https://www.sciencedirect.com/science/article/abs/pii/S1350630721003927
Languages: English-Great Britain (EN-GB)
View in Web of Science | View on publisher site | View citing articles in Web of Science
Abstract
In this paper, the failure cause of a composite soil-cement (CSC) retaining wall is examined during reservoir excavation in the soft clay area of Bangkok, Thailand, by field investigation and threedimensional finite element analyses. A rehabilitation method is also reported. The CSC wall consisted of precast reinforced concrete walls, soil-cement walls, and soil-cement columns encased with a stabilized mat. The original CSC wall configuration was designed based on the maximum soft clay thickness of 4 m found in the excavation areas from seven soil boreholes, providing an FSglobal of 1.61. However, a 50-m-long section of the composite wall failed unexpectedly. The field observation revealed that the wall collapsed from the loss of internal wall stability, namely, broken wall structures caused by bending failure. Continuous circular failure was observed due to the shear failure of the surrounding clays. This failure's primary cause was the unexpected soft clay thickness of 7 m induced by insufficient previous soil explorations. Finite element analyses confirmed that the unanticipated 7-m-thick soft clay facilitated significant failure since the FSglobal value was lower than 1.00. The soil and wall bodies exhibited a collapse because the shear and tensile failure points were fully developed in whole soil bodies and wall structures, respectively. Rehabilitation was performed by revising the original CSC wall configuration for supporting 7-m-thick soft clay, namely, increasing the embedded wall structure lengths and soil-cement rows to strengthen the CSC wall. The revised wall configuration improved the FSglobal during excavation to a value of 1.78, resulting in no visual failure after implementing the rehabilitation. During reservoir operation, the water storage level was kept at a level of -1.00 m to obtain a high FSglobal of 2.33.
Keywords
Composite, Excavation, Failure, Finite Element, Slope stability, Soil-cement wall