Performance Analysis of Ozone Generator for Air purification
Conference proceedings article
Authors/Editors
Strategic Research Themes
Publication Details
Author list: P. Pankaew, J. Emkaew, A. Permsin, S. Arunrungrusmi, N. Mungkung, T. Yuji, and J. Chueaow
Publication year: 2021
Title of series: ICAEME 2021
Number in series: 7
Volume number: 7
Start page: 20
End page: 22
Number of pages: 3
Languages: English-United States (EN-US)
Abstract
Abstract- This study aims to design an ozone system in a private
shoe cabinet for an air purifier. The flyback is used to
generate ozone with a frequency of 35-55 kHz, 6-10 kV dc.
The ozone generator is set up at airflow out the gateway.
The flyback produces ozone at 8 kV dc with ozone
quantity 0.050 ppm within 30 minutes at a cooling High.
An amount of ozone at a high speed is higher than a low speed.
It found that this system produces ozone in safety
boundaries for humans.
Keywords
Air cleaning, Ozone, Plasma