Comparative evaluation of performance and energy consumption of hot air and superheated steam impinging stream dryers for high-moisture particulate materials

Journal article


Authors/Editors


Strategic Research Themes

No matching items found.


Publication Details

Author listChoicharoen K., Devahastin S., Soponronnarit S.

PublisherElsevier

Publication year2011

JournalApplied Thermal Engineering (1359-4311)

Volume number31

Issue number16

Start page3444

End page3452

Number of pages9

ISSN1359-4311

eISSN1873-5606

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-80052031494&doi=10.1016%2fj.applthermaleng.2011.06.030&partnerID=40&md5=6eff9e069c7df872d8614922f644edb0

LanguagesEnglish-Great Britain (EN-GB)


View in Web of Science | View on publisher site | View citing articles in Web of Science


Abstract

Impinging stream dryer (ISD) is a novel alternative to flash dryer for drying high-moisture particulate materials. A number of studies have been conducted on various aspects of an ISD; however, in almost all of the previous studies hot air was used as the drying medium. Since it is well recognized that use of superheated steam as the drying medium could lead to much reduced net energy consumption of the drying process, it was the aim of the present study to investigate the use of superheated steam as the drying medium in an ISD. Okara (soy residue) was used as a test high-moisture particulate material. The performance of the drying system, in terms of the volumetric heat transfer coefficient and volumetric water evaporation rate, as affected by the superheated steam temperature, steam velocity, material feed flow rate and the dryer geometric parameter viz. impinging distance was assessed. In addition, the ability to reuse the exhausted steam as well as the specific energy consumption of the system were evaluated. Comparison was made with the hot air drying results. The maximum volumetric water evaporation rate was found to be around 807 kgwater/m3h, while the maximum volumetric heat transfer coefficient was around 7950 W/m3K at the steam recycle ratios of 46-63%. The lowest total specific energy consumption of the system was around 3.1 MJ/kgwater at an inlet steam temperature of 190 ฐC, inlet steam velocity of 20 m/s, material feed flow rate of 20 kg dry solid/h, impinging distance of 5 cm and steam recycle ratio of 63%. Compared with the hot air drying results at the same corresponding conditions, savings of the total specific energy consumption in the range of 9-46% were noted. ฉ 2011 Elsevier Ltd.


Keywords

Flash dryingSoy residueSteam recycleUnhindered drying rate period


Last updated on 2023-26-09 at 07:35